Fix continuous booting of D-Link DPH-150S

Sometimes D-Link DPH-150S will enter continuous reboot sequence or will stuck at loading screen forever

1 min read
By prox
Fix continuous booting of D-Link DPH-150S

Sometimes D-Link DPH-150S will enter continuous reboot sequence or will stuck at loading screen forever. These steps can help you solve the problem, but you will need to re-configure device from scratch or import previously saved configuration.

Instructions are applicable for DPH-150S F3 and F4 revisions.

Sequence:

  • Turn off DPH-150S
  • Turn on DPH-150S
  • During boot press # key once. You will see POST MODE text.
  • Enter *#168
  • After you will see Configuration reset text, turn off DPH-150S
  • Turn on DPH-150S again. Settings should be cleared and phone will likely boot normaly.

It is possible that after theese steps phone will not come up normally, as it was before, and you will face same boot loop or POST MODE message. In this case you need to rewrite firmware via TFTP.